(1) Criteria applicable to all PSES:
PSES shall be permitted by conditional use only in the I Commercial Industrial Zoning District.
The PSES layout, design and installation shall conform to applicable industry regulations and with all other applicable building, fire and life safety requirements.
All on-site utility transmission lines less than 34.5 kV and plumbing shall be placed underground to the greatest extent feasible.
All PSES shall be situated to eliminate concentrated glare onto nearby structures or roadways.
Signage shall comply with the prevailing sign regulations.
The PSES shall meet the lot size requirements of the applicable zoning district.
PSES shall comply with the following setback requirements:
[1] Building setbacks of the I District shall apply, except that when adjacent to any residential district or parcel, the solar panels must meet a minimum fifty-foot setback. Fencing shall comply with the setbacks of the I District.
[2] If the PSES occupies two or more adjacent properties, setbacks between the adjacent properties shall be waived along the shared property boundaries so that the PSES may be installed continuously and make the most efficient use of the project area.
No PSES shall encroach within any wetlands, wetland buffer, watercourse buffer, steep slopes, floodplains, floodways and/or other sensitive natural areas identified during the conditional use hearing.
(2) Ground-mounted PSES.
The PSES shall meet the lot size requirements of the underlying zoning district.
Setbacks:
[1] PSES shall comply with the setbacks of the underlying zoning districts for principal structures.
[2] Fifty feet from adjacent residential districts or structures.
Ground-mounted PSES shall not exceed 15 feet in height.
Impervious coverage:
[1] The area beneath the ground-mounted PSES is considered pervious cover. However, use of impervious construction materials under the system could cause the area to be considered impervious and subject to the impervious surfaces limitations for the applicable zoning district.
[2] Gravel of paved access roads servicing the PSES shall be considered impervious coverage and calculated as part of the impervious coverage limitations.
Screening and vegetation:
[1] Street screening shall consist of slat fencing or shrubs, six feet to eight feet high when mature, that shall be planted every 15 feet of property abutting a public right-of-way. Shrubs shall be planted adjacent to or outside of the road right-of-way.
[2] Residential buffer screening may be slat fencing or a row of evergreen conifers or broadleaf evergreens spaced in accordance with the chosen species to achieve a continuous visual barrier reaching six feet to eight feet in height within two years of planting. Screening may be a combination of plantings and/or structures with prior approval by the Township.
[3] Perimeter fence shall be placed between shrubs and solar panels.
[4] Widespread use of herbicides to control ground cover growth is prohibited.
[5] The applicant shall agree to, execute and record a maintenance agreement ensuring the continued maintenance of the screening in a manner and form acceptable to the Township, including but not limited to the posting of a performance guarantee.
The ground-mounted PSES shall not be artificially lit except to the extent required for safety or applicable federal, state, or local authority.
Unless agreed to by the easement or right-of-way holder, ground-mounted PSES shall not be placed within any legal easement or right-of-way location, or be placed within any stormwater conveyance system, or in any other manner that would alter or impede stormwater runoff from collecting in a constructed stormwater conveyance system.
Security.
[1] All ground-mounted PSES shall be completely enclosed by a minimum eight-foot high fence with a self-locking gate.
[2] A clearly visible warning sign shall be placed at the base of all pad-mounted transformers and substations and on the fence and on the surrounding the PSES informing individuals of potential voltage hazards.
[3] Access drives to solar inverter stations are required to allow for maintenance and emergency management vehicles. A recommended minimum cartway width is 20 feet.
If a ground-mounted PSES is removed, any earth disturbance as a result of the removal of the ground-mounted solar energy system must be returned to an environmentally stable condition.
(3) Roof- and wall-mounted PSES.
PSES mounted on the roof or wall of any building shall be subject to the maximum height regulations of the underlying zoning district.